Loading SOPGalaxy
SOP Templates & Examples

Nonconformance Report SOP Template

A nonconformance report records that something did not meet a requirement, what was done to contain it, and who decided its fate. This template focuses on the raise-contain-disposition sequence and the criteria for escalating to a deeper investigation.

Template preview

Nonconformance on a failed torque check at assembly

Copy it, download it as Markdown or CSV, or print it. It is a worked example: change the owners, steps and records to fit your process.

WORKED EXAMPLE

Nonconformance Report

Adapt before use

Scenario: An operator finds fasteners below the specified torque on an assembled unit; the report runs from raising to closure.

#StepOwnerWhat happens
1Raise the reportAssembly operatorStop work on the unit, tag it, and complete the report: part number, serial, requirement breached, what was observed, and when. Hand the tagged unit to the supervisor.
2ContainProduction supervisorQuarantine the unit and all units built since the last good torque check. List the serials affected. Check whether any have shipped and tell quality immediately if so.
3Triage and classifyQuality engineerClassify as minor or major using the escalation test. Check the torque tool's calibration status; an out-of-calibration tool widens the containment scope and links to the calibration record.
4Decide dispositionMaterial review groupQuality, engineering and production agree: rework (re-torque and re-inspect) or scrap. A use-as-is decision needs engineering justification in writing and quality approval.
5Execute and verifyProduction supervisorCarry out the disposition, attach rework records, and have an inspector verify. Release quarantined units only after verification.
6Close or escalateQuality managerClose if the cause is isolated and fixed. If the same defect appeared in the last quarter's reports, open a CAPA and link its number to this report.
Document owner: ______Approver: ______Version: ____Next review: ______
Guidance

When to use it, how to adapt it, what to avoid

Good practice

Make it easy to raise. Anyone who sees product, service or a record that fails a requirement should be able to open a report without asking permission. The quality team triages afterwards. If only supervisors may raise them, problems get fixed quietly and never counted.

State the trigger types: failed inspection, supplier material out of spec, process out of limits, customer return with a defect, record missing or wrong.

Keep exploring

Industries, teams and capabilities connected to this template

FAQs

Questions this page often raises

Short, direct answers. Open any question, or expand them all.

What is the difference between a nonconformance and a deviation?
Usage varies by organization. A common distinction is that a deviation is a planned or unplanned departure from a procedure, while a nonconformance is a failure to meet a requirement. Define both in your own SOP and cross-reference the deviation handling template.
Who can close a nonconformance report?
Someone independent of the person who owns the disposition, typically the quality manager or a delegate. Closure should require evidence that containment and disposition are complete.