Temperature Monitoring
Scenario: A chilled warehouse holds product with a critical upper limit and records readings twice per shift.
| # | Step | Owner | What happens |
|---|---|---|---|
| 1 | Check the instrument | Store operative | Confirm the thermometer or logger is within its calibration date and shows plausible values. Out-of-date instruments are swapped before use. |
| 2 | Take and record readings | Store operative | Read each unit at the scheduled times and enter value, time and initials. Never copy a previous reading. |
| 3 | Compare with limits | Store operative | Decision point: within target, continue; above the alert limit, check the door, load and equipment and re-read in a stated time; above the critical limit, go to the excursion step. |
| 4 | Contain and tell | Shift supervisor | Move product if possible, tag affected stock on hold, and notify quality. Record time the unit went out of range. |
| 5 | Assess the product | Quality manager | Decide release, rework or disposal using time above limit and the product specification. Record the decision and signature. |
| 6 | Fix and review | Maintenance lead | Repair the unit, confirm temperature recovery and log the corrective action. Records kept: reading log, calibration records, excursion report, disposition. |